COMPUTE ATLAS Supercomputer supply-chain graph
1581 systems 558 sites Sourced data

Supercomputers/Systems/Snellius (Phase 2 CPU)

Netherlands · operational · hpc

Snellius (Phase 2 CPU)

Also known as Snellius Phase 2 CPU; Snellius Genoa thin nodes

Operated by SURF at SURF (Amsterdam Science Park) .

Researched with AI assistance, checked by scripts. These rows were researched by AI agents reading public operator, laboratory and vendor sources, appended by scripts and checked by automated validation; no subject-matter expert has reviewed them (how this site is made). A mechanical second-reader pass has since fetched every cited source: 1350 of 1581 systems have a readable citation that names them, and 64 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.

Measured performance

Rmax
5.40 PFlop/s
HPL measured
Rpeak
5.71 PFlop/s
Rmax ÷ Rpeak
94.6%
Cores
150,912
Power
799 kW
Per watt
6.8 GF/W

Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.

How it compares

Ranked against the other machines in this dataset that report the same figure: those that first came into service within two years of Snellius (Phase 2 CPU), and those in Netherlands. Computed from our tables; a metric is ranked only when at least eight peers report it.

MetricValueAgainst its eraAgainst its country
Rmax5.40 PFlop/s#173 of 257 · bottom 34%#5 of 11 · top 40%
Energy efficiency6.8 GF/W#105 of 135 · bottom 23%#5 of 8 · bottom 44%
Rmax ÷ Rpeak94.6 %#4 of 256 · top 1%#1 of 11 · highest
Power draw799 kW#59 of 139 · top 42%#3 of 9 · top 25%

Every metric is ranked largest-first, so a high power-draw rank means a big power draw, not a good one. Rmax ÷ Rpeak uses HPL-measured results only. Rankings move as machines are added; they describe this dataset, not the world.

What this machine is made of

One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.

Role Part Supplier at build Quantity Confidence Source
Integrator -
Lenovo ThinkSystem SD665 V3
Lenovo - Reported top500.org
CPU AMD EPYC 9004 (Genoa)
CPUs
x86-64 · 96C · 2.4 GHz · TSMC N5 · 360 W
AMD EPYC 9654 96C 2.4GHz, close to 800 thin nodes
AMD - Reported visualization.surf.nltop500.org
Interconnect NVIDIA InfiniBand NDR (Quantum-2)
Interconnect
Fat tree or dragonfly+ · 400 Gb/s per port · Under 0.6 microseconds
Infiniband NDR200
NVIDIA - Reported top500.org
Operating system Red Hat Enterprise Linux
Operating systems
Linux distribution · Open source, commercial support subscription
RHEL 8.6
Red Hat
IBMNYSE rolls up to IBM
- Reported top500.org

The read

The AMD Genoa thin-node extension of SURF's national supercomputer Snellius. SURF's virtual tour says the Phase 2 extension was put in production in August 2023 and added close to 800 thin nodes with AMD Genoa CPUs plus extra storage, and that the Phase 2 and 3 racks use direct liquid cooling. TOP500 lists it as its own entry: Lenovo ThinkSystem SD665 V3, AMD EPYC 9654 96-core 2.4 GHz, InfiniBand NDR200, RHEL 8.6, 150,912 cores (786 dual-socket nodes of 192 cores by simple division, consistent with SURF's 'close to 800'), Rmax 5.40 and Rpeak 5.71 PFlop/s, 799 kW at measurement level 1 and HPCG 78.9 TFlop/s. SURF's own table of theoretical performance gives 9.3 PFlop/s for all CPU nodes after Phase 2 against 3.2 after Phase 1, which would imply about 6.1 PFlop/s for Phase 2 (a difference of SURF's figures, not a number SURF states) versus TOP500's 5.71. TOP500 rank history: 144th when first listed in November 2023, 165th, 197th (November 2024, the entry recorded here), 230th, 262nd and 287th (June 2026). Sister rows: snellius-phase1-gpu and snellius-phase3-gpu; SURF's Snellius wiki was not reachable, so the node and date facts rest on the virtual tour alone.

Timeline

  • 2023-08 First operational source
  • 2024-11 List debut at #197 (November 2024) source

Public list appearances

Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.

Site & facility

SURF (Amsterdam Science Park)

Location
Amsterdam, Netherlands
Commissioned
2021

Change history

Nearby in scale

The machines closest to Snellius (Phase 2 CPU) by Rmax, smaller to larger.

  • Clementina XXI · Argentina, operational · 5.39 PFlop/s
  • Mahti · Finland, decommissioned · 5.39 PFlop/s
  • Wind River · USA, operational · 5.33 PFlop/s
  • SELENA · France, operational · 5.42 PFlop/s
  • CRESCO8 · Italy, operational · 5.43 PFlop/s
  • Electra · USA, operational · 5.44 PFlop/s

Same site

Further reading