Phase 1 seed dataset, compiled by hand. These rows were built from public operator, laboratory and vendor sources. A mechanical second-reader pass has since fetched every cited source: 1263 of 1345 systems have a readable citation that names them, and 56 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.
Measured performance
- Rmax
- -
- Rpeak
- 459.00 TFlop/s
- Rmax ÷ Rpeak
- -
- Cores
- 9,472
- Power
- -
- Per watt
- - GF/W
Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.
What this machine is made of
One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.
| Role | Part | Supplier at build | Quantity | Confidence | Source |
|---|---|---|---|---|---|
| Integrator | - MEGWARE supplied the system with SlideSX-LC chassis | MEGWARE | - | Reported | megware.comdoku.lrz.de |
| CPU | - Intel Xeon Phi 7210-F Knights Landing, 64 cores, 148 nodes | Intel | 148 reported | Reported | doku.lrz.demegware.com |
| Interconnect | Omni-Path Architecture Interconnect Fat tree · 100 Gb/s per port · About 1 microsecond Intel Omni-Path dual 100 Gbit/s fat tree | Cornelis Networks | - | Reported | doku.lrz.demegware.com |
| Cooling | Direct liquid cooling, warm water Cooling Direct-to-chip cold plates, facility water loop · Removes 90+ percent of node heat to liquid Direct hot-water cooling of nodes, power supplies and Omni-Path switches | MEGWARE | - | Reported | megware.comdoku.lrz.de |
The read
LRZ's hot-water-cooled many-core Linux cluster, supplied by MEGWARE under a contract announced on 30 January 2017 (about 1 million euros, funded by the DFG and the Free State of Bavaria). It has 148 nodes, each with an Intel Xeon Phi 7210-F (Knights Landing, 64 cores, 16 GB MCDRAM) and 96 GB of DDR4, joined by dual 100 Gbit/s Omni-Path in a fat tree with a 1:2 blocking factor; compute and login nodes, power supplies and Omni-Path switches are cooled directly with hot water. LRZ documentation lists 459 TFlop/s peak and a 255 TFlop/s Linpack commitment. The core total is 148 nodes times 64 cores. LRZ now files the page under decommissioned systems without giving a date.
Timeline
- 2017 First operational source
Site & facility
Leibniz Supercomputing Centre, Garching
- Location
- Garching, Germany
- Cooling
- Direct warm-water cooling
- Commissioned
- 2006
Change history
- 2026-10-09 Added CoolMUC-3
Source check
We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.
| Cited source | Result | Found on the page |
|---|---|---|
| doku.lrz.de | blocked our fetch | - |
| megware.com | names system and part | Omni-Path Architecture, Direct liquid cooling, warm water |
Checked 2026-10-13 by pnpm verify. Re-run it and the table changes with the web.
Further reading
Operating a supercomputer
Acceptance testing, why "installed" and "in production" are six months apart, and the machine lifecycle.
Inside a node
Latency-optimised versus throughput-optimised processors, NUMA, and the end of the host-to-device copy.
The interconnect
Topologies, why latency and tail behaviour matter more than bandwidth, and how the fabric market consolidated.